Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Rev. bras. ginecol. obstet ; 43(5): 351-356, May 2021. tab
Article in English | LILACS | ID: biblio-1288563

ABSTRACT

Abstract Objective Most prenatal screening programs for toxoplasmosis use immunoassays in serum samples of pregnant women. Few studies assess the accuracy of screening tests in dried blood spots, which are of easy collection, storage, and transportation. The goals of the present study are to determine the performance and evaluate the agreement between an immunoassay of dried blood spots and a reference test in the serum of pregnant women from a population-based prenatal screening program for toxoplasmosis in Brazil. Methods A cross-sectional study was performed to compare the immunoassays Imunoscreen Toxoplasmose IgM and Imunoscreen Toxoplasmose IgG (Mbiolog Diagnósticos, Ltda., Contagem, Minas Gerais, Brazil)in dried blood spots with the enzymelinked fluorescent assay (ELFA, BioMérieux S.A., Lyon, France) reference standard in the serum of pregnant women from Minas Gerais Congenital Toxoplasmosis Control Program. Results The dried blood spot test was able to discriminate positive and negative results of pregnant women when comparedwith the reference test, with an accuracy of 98.2% for immunoglobulin G (IgG), and of 95.8% for immunoglobulin M (IgM). Conclusion Dried blood samples are easy to collect, store, and transport, and they have a good performance,making this a promisingmethod for prenatal toxoplasmosis screening programs in countries with continental dimensions, limited resources, and a high prevalence of toxoplasmosis, as is the case of Brazil.


Resumo Objetivo A maioria dos programas de triagem pré-natal para toxoplasmose utiliza imunoensaios em amostras de soro de gestantes. Poucos estudos avaliam a acurácia dos testes de triagem em amostras de sangue seco, que são de fácil coleta, armazenamento e transporte. Este estudo teve como objetivo determinar o desempenho e avaliar a concordância entre um imunoensaio em sangue seco e um teste de referência em soro de gestantes de um programa de rastreamento pré-natal de base populacional para toxoplasmose no Brasil. Métodos Realizou-se um estudo transversal para comparar os imunoensaios Imunoscreen Toxoplasmose IgM e Imunoscreen Toxoplasmose IgG (Mbiolog Diagnósticos, Ltda., Contagem, Minas Gerais, Brazil) em sangue seco com o padrão de referência ensaio fluorescente ligado a enzimas (enzyme-linked fluorescent assay, ELFA, BioMérieux S.A., Lion, França) no soro de gestantes do Programa de Controle de Toxoplasmose Congênita de Minas Gerais. Resultados O exame em sangue seco foi capaz de discriminar os resultados positivos e negativos das gestantes quando comparado ao teste de referência, com acurácia de 98,2% para imunoglobulina G (IgG), e de 95,8% para imunoglobulina M (IgM). Conclusão O sangue seco apresenta bom desempenho e é uma amostra de fácil coleta, armazenamento e transporte, o que o torna um método promissor para programas de triagem pré-natal de toxoplasmose em países com dimensões continentais, recursos limitados, e alta prevalência de toxoplasmose, como é o caso do Brasil.


Subject(s)
Humans , Female , Pregnancy , Toxoplasma/isolation & purification , Toxoplasmosis/diagnosis , Toxoplasmosis, Congenital/diagnosis , Immunoenzyme Techniques/methods , Dried Blood Spot Testing/methods , Prenatal Diagnosis , Toxoplasma/immunology , Brazil/epidemiology , Immunoglobulin G/blood , Immunoglobulin M/blood , Antibodies, Protozoan/blood , Toxoplasmosis/epidemiology , Toxoplasmosis, Congenital/epidemiology , Mass Screening , Population Surveillance , Prevalence , Cross-Sectional Studies , Pregnant Women
2.
Biomedical and Environmental Sciences ; (12): 257-264, 2021.
Article in English | WPRIM | ID: wpr-878357

ABSTRACT

Objective@#The aim of the present study was to evaluate the performance of the simultaneous detection of HIV-1 RNA, HIV-1 DNA, and HCV RNA using one dried blood spot (DBS) as an alternative sample to plasma.@*Method@#A total of 571 paired DBS/plasma samples were collected from men who have sex with men (MSM) and injection drug users (IDUs), and serological and molecular assays were performed. Using plasma results as the reference standard, the performance of DBS tests for HIV-1 RNA, HIV-1 DNA, and HCV RNA was evaluated. Pearson's correlation coefficients and Bland-Altman analysis were performed to assess the correlation and concordance between DBS and plasma.@*Results@#Among paired plasma/DBS samples with detectable HIV-1 RNA and HCV RNA, five samples (5/32) were not detectable in DBS, while measurable HIV-1 RNA levels were present in plasma (1.44 to 3.99 log @*Conclusion@#The performance of the simultaneous detection of HIV-1 RNA, HIV-1 DNA, and HCV RNA using one DBS was acceptable. DBS, as an alternative sample to plasma, may be a viable option for the simultaneous detection of HIV-1 RNA, HIV-1 DNA, and HCV RNA in resource-limited settings or for individuals living in areas that are difficult to access.


Subject(s)
DNA, Viral/analysis , Diagnostic Tests, Routine/methods , Dried Blood Spot Testing/methods , HIV Infections/diagnosis , HIV-1/isolation & purification , Hepacivirus/isolation & purification , Hepatitis C/diagnosis , RNA, Viral/analysis , Sensitivity and Specificity , Specimen Handling/methods , Syphilis/diagnosis , Treponema pallidum/isolation & purification
3.
Medicina (B.Aires) ; 80(3): 197-202, jun. 2020. ilus, tab
Article in English | LILACS | ID: biblio-1125070

ABSTRACT

Congenital adrenal hyperplasia (CAH) is an autosomal recessive disorder due to a deficiency of enzymes involved in cortisol biosynthesis. In more than 90% of cases, CAH is secondary to deleterious mutations in the CYP21A2 gene leading to 21-hydroxilase deficiency (21OHD). The CYP21A2 gene is located on the short arm of chromosome 6 (6p21·3) and encodes the cytochrome P450C21 enzyme. Neonatal screening programs detect the classic forms of CAH-21OHD quantifying 17OH-progesterone in dried blood spots (DBS). This test is very sensitive, but it has a low specificity, requiring a second sample to confirm the result. In these cases, a second-tier test in the same sample may be useful. Our aim was to evaluate a DNA extraction method from DBS and assess the performance of such DNA in the molecular analysis of the CYP21A2 gene mutations. Twelve individuals, who presumably had CAH based on the initial neonatal screening results, were analyzed using DNA extracted from freshly collected blood on EDTA and DBS. The CYP21A2 gene was analyzed by automated sequencing of all exons and intron boundaries and MLPA analysis in DBS. Molecular analysis results from both extraction methods were compared. In this study, we show that DNA extracted from neonatal screening DBS is a useful tool to define CYP21A2 gene mutations in 21-OHD diagnostic confirmation for the newborn screening program and that its results are comparable to traditional genotyping.


La hiperplasia suprarrenal congénita (HSC) es un desorden autosómico recesivo producido por la deficiencia de alguna de las enzimas involucradas en la biosíntesis de cortisol. Más del 90% se debe a mutaciones en el gen CYP21A2 que genera deficiencia de 21 hidroxilasa (21OHD). Este gen se encuentra en el brazo corto del cromosoma 6 (6p21·3) y codifica para la enzima citocromo P450C21. Los programas de pesquisa neonatal detectan la forma clásica de la HSC-21OHD cuantificando 17OH-progesterona en gota de sangre en papel de filtro (GSPF). Este test es muy sensible, pero tiene baja especificidad , por lo que se utiliza una segunda muestra para confirmar el resultado. En estos casos, una segunda determinación en la misma muestra podría ser de utilidad. Nuestro objetivo fue evaluar el método de extracción de ADN y posterior análisis molecular del gen CYP21A2 en muestras de GSPF. Analizamos doce individuos presumiblemente afectados por HSC en la pesquisa neonatal usando ADN extraído de sangre fresca recolectada sobre EDTA y de GSPF. Realizamos el análisis del gen CYP21A2 mediante secuenciación automática de todos los exones y regiones intrónicas flanqueantes y MLPA en GSPF, y comparamos los resultados con ambos métodos de extracción. En este estudio demostramos que el ADN extraído de GSPF es una herramienta muy útil para analizar las mutaciones del gen CYP21A2 en la confirmación diagnóstica de 21-OHD para los programas de pesquisa neonatal y que los resultados son comparables con la genotipificación tradicional.


Subject(s)
Humans , Male , Female , Infant, Newborn , Steroid 21-Hydroxylase/genetics , Neonatal Screening/methods , Adrenal Hyperplasia, Congenital/diagnosis , Adrenal Hyperplasia, Congenital/genetics , Dried Blood Spot Testing/methods , Mutation , Reference Values , Spectrophotometry , Polymerase Chain Reaction , Reproducibility of Results , Gestational Age , 17-alpha-Hydroxyprogesterone/analysis , Alleles
4.
Rev. Soc. Bras. Med. Trop ; 48(supl.1): 87-97, 2015. tab, graf
Article in English | LILACS | ID: lil-748368

ABSTRACT

INTRODUCTION : In 2011, the Brazilian Ministry of Health rolled out a program for the external quality assessment of rapid human immunodeficiency virus (HIV) tests using the dried tube specimen (DTS) method (EQA-RT/DTS-HIV). Our objective was to evaluate the implementation of this program at 71 voluntary counseling and testing centers (VCTCs) in the Brazilian Legal Amazonian area one year after its introduction. METHODS : Quantitative and qualitative study that analyzed secondary data and interviews with healthcare workers (HCWs) (n=39) and VCTC coordinators (n=32) were performed. The assessment used 18 key indicators to evaluate the three dimensions of the program's logical framework: structure, process, and result. Each indicator was scored from 1-4, and the aggregate results corresponding to the dimensions were expressed as proportions. The results were compared to the perceptions of the HCWs and coordinators regarding the EQA-RT/DTS-HIV program. RESULTS: The aggregate scores for the three dimensions of structure, process, and result were 91.7%, 78.6%, and 95%, respectively. The lowest score in each dimension corresponded to a different indicator: access to Quali-TR online system 39% (structure), registration in Quali-TR online system 38.7% (process), and VCTC completed the full process in the program's first round 63.4% (result). Approximately 36% of the HCWs and 52% of the coordinators reported enhanced trust in the program for its rapid HIV testing performance. CONCLUSIONS: All three program dimensions exhibited satisfactory results (>75%). Nevertheless, the study findings highlight the need to improve certain program components. Additionally, long-term follow-ups is needed to provide a more thorough picture of the process for external quality assessment. .


Subject(s)
Humans , Dried Blood Spot Testing/standards , HIV Infections/diagnosis , Quality Assurance, Health Care , Brazil , Counseling , Dried Blood Spot Testing/methods
5.
Braz. j. infect. dis ; 18(6): 618-624, Nov-Dec/2014. tab
Article in English | LILACS | ID: lil-730415

ABSTRACT

Introduction: Screening for vertically transmitted infection is mandatory and must be conducted at the first prenatal consultation. The most vulnerable women's groups are those at the lowest socio-economic level. Dried blood spot testing on filter paper could represent a secure way to screen pregnant women in the prenatal period. Methods: A cross-sectional study was conducted between November 2009 and March 2010, in the Metropolitan Region of Salvador, Bahia, Brazil, to compare the accuracy of the dried blood spot in filter paper and venipuncture serological as screening methods for HIV, HTLV, VHB, VHC, Treponema pallidum, and Toxoplasma gondii during prenatal period. Results of the venous blood sample collected in tubes were considered the gold standard. Results: Serum samples and dried blood spot were obtained from 692 pregnant women aged between 14 and 42 years, with a median age of 26. Thirteen women were seropositive for T. gondii (1.88%; 95% CI: 0.60–2.71%), five for T. pallidum (0.72%; 95% CI: 0.15–1.61%), two for HBV (0.29%; 95% CI: 0.050.95%) and one for HTLV-1 (0.14%; 95% CI: 0.01–0.71%). No one was positive for HCV and HIV. The dried blood spot accuracy for syphilis and HTLV were 100% (95% CI: 99.25–100) and 100% (95% CI: 99.45–100%), respectively. The average time between blood collection and recording of the sample in the reference laboratory was 4.93 (3.82) days and between dried blood spot processing and active search for pregnant women was 3.44 (4.27) days. Conclusions: The use of dried blood spot may represent a secure way to expedite access to results of vertically transmitted diseases in the prenatal period, particularly in regions with scarce healthcare resources. .


Subject(s)
Adolescent , Adult , Female , Humans , Pregnancy , Young Adult , Dried Blood Spot Testing/methods , Pregnancy Complications, Infectious/diagnosis , Brazil/epidemiology , Cross-Sectional Studies , HIV Infections/diagnosis , HIV Infections/epidemiology , HTLV-I Infections/diagnosis , HTLV-I Infections/epidemiology , HTLV-II Infections/diagnosis , HTLV-II Infections/epidemiology , Hepatitis B/diagnosis , Hepatitis B/epidemiology , Hepatitis C/diagnosis , Hepatitis C/epidemiology , Prenatal Diagnosis , Prevalence , Reproducibility of Results , Syphilis/diagnosis , Syphilis/epidemiology , Toxoplasmosis/diagnosis , Toxoplasmosis/epidemiology
6.
J. bras. pneumol ; 39(5): 547-554, Sep-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-695178

ABSTRACT

OBJECTIVE: To validate and develop an immunonephelometric assay for the determination of alpha-1 antitrypsin (AAT) levels in dried blood spots from COPD patients in Brazil. METHODS: We determined AAT levels in serum samples and dried blood spots from 192 COPD patients. For the preparation of dried blood spots, a disk (diameter, 6 mm) was placed into a tube, eluted with 200 µL of PBS, and stored overnight at 4ºC. All of the samples were analyzed by immunonephelometry in duplicate. We used the bootstrap resampling method in order to determine a cut-off point for AAT levels in dried blood spots. RESULTS: The correlation coefficient between the AAT levels in serum samples and those in dried blood spots was r = 0.45. For dried blood spots, the cut-off value was 2.02 mg/dL (97% CI: 1.45-2.64 mg/dL), with a sensitivity, specificity, positive predictive value, and negative predictive value of 100%, 95.7%, 27.2%, and 100%, respectively. CONCLUSIONS: This method for the determination of AAT levels in dried blood spots appears to be a reliable screening tool for patients with AAT deficiency. .


OBJETIVO: Validar e desenvolver um método de dosagem de alfa-1 antitripsina (AAT) por imunonefelometria em amostras de sangue em papel-filtro em pacientes com DPOC no Brasil. MÉTODOS: Amostras de soro e de sangue em papel-filtro de 192 pacientes com DPOC foram utilizadas para a dosagem de AAT. Para a preparação das amostras de sangue em papel-filtro, um disco do papel com diâmetro de 6 mm foi colocado em um tubo e eluído com 200 µL de PBS, permanecendo por toda a noite a 4ºC. Todas as amostras foram analisadas em duplicata por imunonefelometria. O método de reamostragem bootstrap foi utilizado para a determinação de um ponto de corte para o nível de AAT nas amostras de sangue em papel-filtro. RESULTADOS: O coeficiente de correlação entre os níveis de AAT em soro e em sangue em papel-filtro foi de r = 0,45. Para as amostras em papel-filtro, o ponto de corte foi de 2,02 mg/dL (IC97%: 1,45-2,64 mg/dL), com sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo de 100%, 95,7%, 27,2% e 100%, respectivamente. CONCLUSÕES: Este método de determinação dos níveis de AAT em sangue em papel-filtro se mostrou uma ferramenta confiável para o rastreamento de pacientes com deficiência de AAT. .


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Dried Blood Spot Testing/methods , Immunologic Tests/methods , Nephelometry and Turbidimetry/methods , Pulmonary Disease, Chronic Obstructive/diagnosis , alpha 1-Antitrypsin Deficiency/diagnosis , alpha 1-Antitrypsin/blood , Brazil , Cross-Sectional Studies , Mass Screening , Outpatients , Predictive Value of Tests , Reference Standards
7.
Braz. j. med. biol. res ; 45(6): 546-556, June 2012. ilus, tab
Article in English | LILACS | ID: lil-622782

ABSTRACT

Acylcarnitine profiling by electrospray ionization tandem mass spectrometry (ESI-MS/MS) is a potent tool for the diagnosis and screening of fatty acid oxidation and organic acid disorders. Few studies have analyzed free carnitine and acylcarnitines in dried blood spots (DBS) of umbilical cord blood (CB) and the postnatal changes in the concentrations of these analytes. We have investigated these metabolites in healthy exclusively breastfed neonates and examined possible effects of birth weight and gestational age. DBS of CB were collected from 162 adequate for gestational age neonates. Paired DBS of heel-prick blood were collected 4-8 days after birth from 106 of these neonates, the majority exclusively breastfed. Methanol extracts of DBS with deuterium-labeled internal standards were derivatized before analysis by ESI-MS/MS. Most of the analytes were measured using a full-scan method. The levels of the major long-chain acylcarnitines, palmitoylcarnitine, stearoylcarnitine, and oleoylcarnitine, increased by 27, 12, and 109%, respectively, in the first week of life. Free carnitine and acetylcarnitine had a modest increase: 8 and 11%, respectively. Propionylcarnitine presented a different behavior, decreasing 9% during the period. The correlations between birth weight or gestational age and the concentrations of the analytes in DBS were weak (r £ 0.20) or nonsignificant. Adaptation to breast milk as the sole source of nutrients can explain the increase of these metabolites along the early neonatal period. Acylcarnitine profiling in CB should have a role in the early detection of metabolic disorders in high-risk neonates.


Subject(s)
Female , Humans , Infant, Newborn , Male , Breast Feeding , Carnitine/analogs & derivatives , Fetal Blood/chemistry , Neonatal Screening , Tandem Mass Spectrometry/methods , Brazil , Carnitine/blood , Dried Blood Spot Testing/methods , Fatty Acids/metabolism , Statistics, Nonparametric , Spectrometry, Mass, Electrospray Ionization/methods
SELECTION OF CITATIONS
SEARCH DETAIL